ASCII - Command CARDSAVE    
Syntax Transmit CARDSAVE    
Syntax Receive CARDSAVE   Available in  
Type Command   MMI No
ASCII Format Command   CANBus Object Number -
DIM -   PROFIBUS PNU -
Range     DPR No
Default -    
Opmode All   Data Type Bus/DPR -
Drive State Disabled   Weighting  
Start Firmware 3.60    
Configuration No   Last Change of this Object  
Function Group SD-Card   EEPROM No
Short Description save data from the drive to the SD memory card

Description

CARDSAVE <Option> “name"

Saves firmware/data component of the S700 to the card with filename "name". CARDSAVE concern the amplifier's firmware, and must therefore be operated with disabled output stage. When the command is finished, the amplifier is restarted automatically. Save and load of amplifier parameters (option PARAM) or Safety parameters (option SAFETY) can be operated with enabled output stage. Nearly all data which have been saved with the command CARDSAVE are binary coded, except the parameter file saved by CARDSAVE PARAM, that is saved as ASCII file. This file can be read and edit with the setup software DriveGUI.