ASCII - Command CSENID    
Syntax Transmit CSENID [Data]    
Syntax Receive CSENID <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer8   CANBus Object Number 38CB (hex)
DIM     PROFIBUS PNU 1771 (dec) IND = 33 (dec)
Range 0 / 1   DPR 971 (dec)
Default -    
Opmode All   Data Type Bus/DPR Integer8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 5.00    
Configuration Yes   Last Change of this Object 2.13
Function Group safety   EEPROM Yes
Short Description reactive current impression

Description

CSENID enables the impression of an reactive current (Id) if the active current portion (Iq) is not sufficient for the safety card.

The maximum value for the reactive current can be set via CSIDMAX. Id will be automatically reduced if Iq increases. Id is zero if Iq reaches CSIDMAX.

CSENID =1 will activate the reactive current impression (only if a safety card is installed).

Note: If the safety card is removed, the value for CSENID must reset to 0, otherwise a slot fault (F20) will be generated.