ASCII - Command EN    
Syntax Transmit EN    
Syntax Receive EN   Available in  
Type Command   MMI Yes
ASCII Format Command   CANBus Object Number 3530 (hex)
DIM -   PROFIBUS PNU 1648 (dec) IND = 1 (dec)
Range -   DPR 48 (dec)
Default -    
Opmode All   Data Type Bus/DPR -
Drive State Disabled   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group control commands   EEPROM No
Short Description Software-Enable

Description

The EN command sets the software enable for the output stage.
If the software enable and the hardware enable are set and no fault is present (the BTB contact is closed), then the output stage is enabled.
If the MAINS BTB function is activated (OxMODE=3), then the output stage will only be enabled when the supply power has been switched on and the charging circuit has charged up the DC bus. If the supply power is removed from an enabled instrument, then it remains enabled until the DC bus voltage has fallen below the undervoltage limit (VBUSMIN).