ASCII - Command EN22CNFG    
Syntax Transmit EN22CNFG [Data]    
Syntax Receive EN22CNFG <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer16   CANBus Object Number 390F (hex)
DIM -   PROFIBUS PNU 1839 (dec) IND = 33 (dec)
Range 0 .. 3   DPR 1039 (dec)
Default 1    
Opmode All   Data Type Bus/DPR Integer16
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 5.91    
Configuration Yes   Last Change of this Object 2.13
Function Group feedback   EEPROM Yes
Short Description Config.parameter for ENDAT 2.2 additional information

Description

This parameter is a bit variable. Setting a bit activates the reading of the corresponding ENDAT2.2 additional information.

Bit 0 = 1 Reading in the diagnostic information (evaluation values)
Bit 1 = 1 Reading the additional information 1
Bit 2 = 1 Reading the additional information 2

Setting a bit to 0 inhibits the reading of the associated additional information