ASCII - Command EN22DCNT    
Syntax Transmit EN22DCNT    
Syntax Receive EN22DCNT <Data>   Available in  
Type Variable ro   MMI No
ASCII Format Integer16   CANBus Object Number 3910 (hex)
DIM -   PROFIBUS PNU 1840 (dec) IND = 33 (dec)
Range 0 .. 65535   DPR 1040 (dec)
Default -    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 5.91    
Configuration No   Last Change of this Object 2.12
Function Group feedback   EEPROM No
Short Description Endat 2.2 status of the diagnostic information

Description

This parameter is a bit variable. If the bit is set, the associated diagnostic information is available. If the bit isn't set, the corresponding information is not supported by the ENDAT2.2 encoder.

The individual bits are assigned the following information:

Bit 0 - Evaluation number 1
Bit 1 - Evaluation number 2
Bit 2 - Evaluation number 3
Bit 3 - Rating number 4
Bit 4 - Evaluation number 5
Bit 5 - Evaluation number 6
Bit 6 ... 14 is free
Bit 15 - system specific data