ASCII - Command HALLDIR    
Syntax Transmit HALLDIR [Data]    
Syntax Receive HALLDIR <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer8   CANBus Object Number 3550 (hex)
DIM -   PROFIBUS PNU 1680 (dec) IND = 1 (dec)
Range -1 .. 1   DPR 80 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.00    
Configuration Yes   Last Change of this Object 2.13
Function Group feedback   EEPROM Yes
Short Description Hall segment table number

Description

In the S300 firmware there are 2 tables with hall segment numbers.

HALLDIR = 0: order of hall segments 1,5,4,6,2,3
HALLDIR = 1: order of hall segments 1,3,2,6,4,5

The correct table number can be determined by moving the motor in the positive direction (velocity > 0)
And checking the order of the hall segments with the macro command (M SR_HALL).