ASCII - Command | HIFACT1 | For Manufacturer Use only | ||
Syntax Transmit | HIFACT1 [Data] | |||
Syntax Receive | HIFACT1 <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Integer16 | CANBus Object Number | 3553 (hex) | |
DIM | - | PROFIBUS PNU | 1683 (dec) IND = 1 (dec) | |
Range | 10000 .. 32767 | DPR | 83 (dec) | |
Default | 16384 | |||
Opmode | All | Data Type Bus/DPR | Integer16 | |
Drive State | - | Weighting | ||
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 1.0 | |
Function Group | feedback | EEPROM | Encoder | |
Short Description | Hiperface: Sin/Cos Gain Factor (incremental track) |
Description
The HIFACT1 command sets the amplitude scaling for the sine signal of the absolute track (SinCoder). The amplitude scaling is for the value 16384 = 1. The command is only available when a sin/cos encoder has been selected as the feedback device (FBTYPE=2,4,7). Depending on the type of encoder used, the HIFACT1 setting is stored in the EEPROM of the encoder (FBTYPE=2,4, command HSAVE). When using an encoder without a parameter channel (FBTYPE=7), and thus without an internal EEPROM, this setting will be saved in the EEPROM of the amplifier (command SAVE). |