ASCII - Command IN3    
Syntax Transmit IN3 [Data]    
Syntax Receive IN3 <Data>   Available in  
Type Variable ro   MMI Yes
ASCII Format Integer8   CANBus Object Number 3567 (hex)
DIM -   PROFIBUS PNU 1703 (dec) IND = 1 (dec)
Range 0 .. 1   DPR 103 (dec)
Default -    
Opmode All   Data Type Bus/DPR Integer8
Drive State -   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group digital I/O   EEPROM No
Short Description Status of Digital Input 3

Description

The status of the digital input INPUT3.