ASCII - Command | IPEAK | |||
Syntax Transmit | IPEAK [Data] | |||
Syntax Receive | IPEAK <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 356E (hex) | |
DIM | A | PROFIBUS PNU | 1710 (dec) IND = 1 (dec) | |
Range | 0.0 ... DIPEAK | DPR | 110 (dec) | |
Default | IMAX | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 2.12 | |
Function Group | current loop | EEPROM | Yes | |
Short Description | Application Peak Current |
Description
IPEAK sets the peak rated current IPEAKP and IPEAKN of the application (RMS value). The value to be entered is limited to the lower of the peak rated current of the motor (MIPEAK) or amplifier (DIPEAK). If the IPEAK value is too low, the drive shows following errors and the peak torque is too low. If the IPEAK value is too high, the motor is endangered. |