ASCII - Command MAXTEMPE    
Syntax Transmit MAXTEMPE [Data]    
Syntax Receive MAXTEMPE <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 3584 (hex)
DIM Centigrade Degrees   PROFIBUS PNU 1732 (dec) IND = 1 (dec)
Range 10 .. 80   DPR 132 (dec)
Default 75    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.8
Function Group temperatures   EEPROM Yes
Short Description Ambient Temperature Switch off Threshold

Description

The ambient temperature value for switching off the power stage and opening the BTB / RTO contact. If the drive temperature (as given by TEMPE) exceeds this value, the drive faults (F13).