ASCII - Command MAXTEMPM    
Syntax Transmit MAXTEMPM [Data]    
Syntax Receive MAXTEMPM <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Float   CANBus Object Number 3586 (hex)
DIM Ohms or [MTAB units]   PROFIBUS PNU 1734 (dec) IND = 1 (dec)
Range -6000.0 .. 6000.0   DPR 134 (dec)
Default 300    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.10
Function Group temperatures   EEPROM Yes
Short Description Motor Temperature Switch off Threshold

Description

The motor temperature for switching off (defined by the resistance in ohms).

MAXTEMPM = 0 switches off the monitoring of the motor temperature (F06)

In existing temperature characteristic (see MTAB) the units change for the parameter MAXTEMPM and TEMPM of Ohm to the unit that was used in the characteristic definition.

see also SLTEMPM, TEMPM, MTAB