ASCII - Command MPKD    
Syntax Transmit MPKD [Data]    
Syntax Receive MPKD <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer32   CANBus Object Number 3870 (hex)
DIM -   PROFIBUS PNU 1680 (dec) IND = 33 (dec)
Range -   DPR 880 (dec)
Default 10000    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting  
Start Firmware 2.53    
Configuration No   Last Change of this Object 2.0
Function Group wake&shake   EEPROM Yes
Short Description D-Term for the commutation alignment PID position loop

Description

D-Term for the commutation alignment PID position loop (CALCMP)