ASCII - Command | MRS | |||
Syntax Transmit | MRS [Data] | |||
Syntax Receive | MRS <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Float | CANBus Object Number | 3686 (hex) | |
DIM | Ohms | PROFIBUS PNU | 1990 (dec) IND = 1 (dec) | |
Range | 0 .. 200 | DPR | 390 (dec) | |
Default | 1 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 2.13 | |
Function Group | other commands | EEPROM | Yes | |
Short Description | Winding Resistance of the Stator Phase-Phase |
Description
The parameter describes the stator winding resistance phase-phase in Ohm |