ASCII - Command | PASSCNFG | |||
Syntax Transmit | PASSCNFG [Data] | |||
Syntax Receive | PASSCNFG <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Integer8 | CANBus Object Number | 36D8 (hex) | |
DIM | - | PROFIBUS PNU | 1672 (dec) IND = 17 (dec) | |
Range | 0 .. 2 | DPR | 472 (dec) | |
Default | 0 | |||
Opmode | Data Type Bus/DPR | Integer8 | ||
Drive State | Weighting | |||
Start Firmware | 3.00 | |||
Configuration | No | Last Change of this Object | 2.10 | |
Function Group | drive configuration | EEPROM | ||
Short Description | Password Function |
Description
The command PASSCNFG sets the passwort-function. PASSCNFG = 0 all parameter writing procedures are locked PASSCNFG = 1 only parameter SAVE is locked PASSCNFG = 2 parameter access isn't possible (no reading and no writing). Only the command PASS is permitted PASSCNFG = 3 commands RSTVAR and SAVE are not allowed and only after entering a password (PASS/PASSX) are executed. Please have a look to: PASS, PASSX |