ASCII - Command PBALRES    
Syntax Transmit PBALRES [Data]    
Syntax Receive PBALRES <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer8   CANBus Object Number 35C2 (hex)
DIM -   PROFIBUS PNU 1794 (dec) IND = 1 (dec)
Range 0 ... 200   DPR 194 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.0    
Configuration Yes   Last Change of this Object 1.0
Function Group drive configuration   EEPROM Yes
Short Description Select Regen Resistor

Description

This parameter can be used to select whether the internal (0) or an external (> 0) regen resistor should be used.The value > 0 sets the regen resistor in ohm.

Note: The allowed resistor value depends to the used drive type. Look into the installation manuel for the data, please.

It affects the PBALMAX parameter.