ASCII - Command PMODE    
Syntax Transmit PMODE [Data]    
Syntax Receive PMODE <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer8   CANBus Object Number 35CD (hex)
DIM -   PROFIBUS PNU 1805 (dec) IND = 1 (dec)
Range 0 .. 8   DPR 205 (dec)
Default (0) 1    
Opmode All   Data Type Bus/DPR Integer32
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.0    
Configuration Yes   Last Change of this Object 2.14
Function Group drive configuration   EEPROM Yes
Short Description Line Phase Mode

Description

Theis parameter configurate the line phase mode

only for the S30x - not available on S34x!
PMODE=0 single phase operation (current limit)

for S300/S700
PMODE=1 three phase operation, current limited and warning n05 in case of network phase missing
PMODE=2 three phase operation, error message F19 in case of DC bus break down
PMODE=3 three phase operation, current limited and warning n05 in case of network phase missing
PMODE=4 direct DC feed
PMODE=5 such als PMODE=1, the warning or fault is generated by enabled drive
PMODE=6 such als PMODE=2, the warning or fault is generated by enabled drive
PMODE=7 such als PMODE=3, the warning or fault is generated by enabled drive
PMODE=8 reserved

If the current limiting is activated, it only applies to periods of acceleration. A braking operation can still be carried out at full current.