ASCII - Command SSIINV    
Syntax Transmit SSIINV [Data]    
Syntax Receive SSIINV <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer8   CANBus Object Number 35F7 (hex)
DIM -   PROFIBUS PNU 1847 (dec) IND = 1 (dec)
Range 0 .. 3   DPR 247 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer8
Drive State Disable   Weighting  
Start Firmware 3.55    
Configuration No   Last Change of this Object 2.1
Function Group feedback   EEPROM Yes
Short Description polarity of SSI Clock

Description

nur S300:

The behavior of the SSI interface at X5.
The SSIINV command has different interpretations, depending on whether the SSI is configured as an output or an input.

1. SSI output
SSIINV = 0: normal clock level
SSIINV = 1: inverted clock level
SSIINV = 2: normal clock level, only 12 Bit resolution
SSIINV = 3: inverted clock level, only 12 Bit resulotion