ASCII - Command | SSIINV | |||
Syntax Transmit | SSIINV [Data] | |||
Syntax Receive | SSIINV <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Integer8 | CANBus Object Number | 35F7 (hex) | |
DIM | - | PROFIBUS PNU | 1847 (dec) IND = 1 (dec) | |
Range | 0 .. 3 | DPR | 247 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer8 | |
Drive State | Disable | Weighting | ||
Start Firmware | 3.55 | |||
Configuration | No | Last Change of this Object | 2.1 | |
Function Group | feedback | EEPROM | Yes | |
Short Description | polarity of SSI Clock |
Description
nur S300: The behavior of the SSI interface at X5. The SSIINV command has different interpretations, depending on whether the SSI is configured as an output or an input. 1. SSI output SSIINV = 0: normal clock level SSIINV = 1: inverted clock level SSIINV = 2: normal clock level, only 12 Bit resolution SSIINV = 3: inverted clock level, only 12 Bit resulotion |