ASCII - Command SSITOUT    
Syntax Transmit SSITOUT [Data]    
Syntax Receive SSITOUT <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer8   CANBus Object Number 3661 (hex)
DIM -   PROFIBUS PNU 1953 (dec) IND = 1 (dec)
Range 0 .. 3   DPR 353 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.0    
Configuration Yes   Last Change of this Object 2.10
Function Group feedback   EEPROM Yes
Short Description Transmit setting time SSI

Description

The command SSIOUT sets the monoflop - setting time of the SSI - transmittion.

SSI - OUTPUT:
SSITOUT = 0 <= setting time 13 µsec
SSITOUT = 1 <= setting time 3 µsec

since FW 5.87:
SSITOUT = 2 <= setting time 8 µsec
SSITOUT = 3 <= free programmable settling time (input via the parameter SSITIME)

SSI - INPUT:
This parameter defines the clock-frequency, which is used for the read of the SSI-data word.

SSITOUT 0: 1MHz only for 1. & 2. feedback (FBTYPE, EXTPOS)
SSITOUT 1: 500 kHz only for 1. & 2. feedback (FBTYPE, EXTPOS)
SSITOUT 2: 250 kHz only for second feedback (EXTPOS)
SSITOUT 3: 125 kHz only for second feedback (EXTPOS)