ASCII - Command STOP    
Syntax Transmit STOP    
Syntax Receive STOP   Available in  
Type Command   MMI Yes
ASCII Format Command   CANBus Object Number 35FE (hex)
DIM -   PROFIBUS PNU 1854 (dec) IND = 1 (dec)
Range -   DPR 254 (dec)
Default -    
Opmode All   Data Type Bus/DPR -
Drive State Enabled   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group control commands   EEPROM No
Short Description adjust setpoint to 0

Description

The STOP command breaks off the drive movement. The response of the drive varies according to the operating mode that is valid at the moment.

1. OPMODE=0 (digital velocity control)
The STOP command has the effect of setting the velocity setpoint to 0.
The drive brakes along the preset braking ramp for the velocity control loop (DEC).

2. OPMODE=2 (digital current control)
The STOP command has the effect of setting the current setpoint to 0.
The drive coasts down.

3. OPMODE=8 (internal motion tasks)
The STOP command has the effect of breaking off the present motion task (jog mode / homing movement).
The drive brakes along the decel ramp that is defined in the motion task. The motion task can be restarted by CONTINUE or digital input defined with INxMODE=22.

The STOP command has no function in the OPMODE=1,3,4,5,6,7 operating modes.