ASCII - Command | UMAX | |||
Syntax Transmit | UMAX [Data] | |||
Syntax Receive | UMAX <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | - | CANBus Object Number | - | |
DIM | PROFIBUS PNU | - | ||
Range | 0 .. 2000 | DPR | No | |
Default | 1900 | |||
Opmode | Data Type Bus/DPR | - | ||
Drive State | Weighting | |||
Start Firmware | ||||
Configuration | No | Last Change of this Object | 2.7 | |
Function Group | other commands | EEPROM | ||
Short Description | maximal output voltage at field weakening |
Description
UMAX is a parameter for using a induction maschine and describes the maximal output voltage at field weakening. |