ASCII - Command VLIMP    
Syntax Transmit VLIM [Data]    
Syntax Receive VLIMP <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Float   CANBus Object Number 3622 (hex)
DIM ( > VUNIT)   PROFIBUS PNU 1890 (dec) IND = 1 (dec)
Range 0.0 .. MSPEED   DPR 290 (dec)
Default 3000    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.14
Function Group velocity loop   EEPROM Yes
Short Description Max. velocity

Description

The VLIMN parameter defines the maximum velocity for the positiv direction (velocity control loop) in units defined by VUNIT.
VLIMPis also used for limiting PVMAXN:
PVMAXP <= (VLIMP * PGEARI * 2^PRBASE) / (60 * PGEARO)

When used together with the VLIMN parameter, it is possible to implement a directionally-dependent rotational velocity limit. The VLIMN command determines the maximum velocity for the negative direction.