ASCII - Command VLO    
Syntax Transmit VLO [Data]    
Syntax Receive VLO <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 363D (hex)
DIM -   PROFIBUS PNU 1917 (dec) IND = 1 (dec)
Range 0 ... 30   DPR 317 (dec)
Default 0.5    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group feedback   EEPROM Yes
Short Description Software resolver/digital converter feedforward

Description

VLO is a parameter of the Luenberger Velocity Observer. To reduce the delay of the derivation the observer can be served with the torque component of the current. The effective inertia is estimated by the gain of the velocity loop (GV). Setting VLO to zero the acceleration will not influence the observer. With a value of 1 the acceleration is full enabled. With VLO 0.5 the Observer will use 50% of the acceleration torque. Reducing VLO can result in an instable velocity loop.