ASCII - Command WMASK    
Syntax Transmit WMASK [Data]    
Syntax Receive WMASK <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer32   CANBus Object Number 363E (hex)
DIM -   PROFIBUS PNU 1918 (dec) IND = 1 (dec)
Range -21474836470 ... 21474836470   DPR 318 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group drive configuration   EEPROM No
Short Description Warning as fault mask

Description

The WMASK parameter can be used to reconfigure a warning as the fault message F24.
The WMASK parameter is a bit-variable, with bit assignments that correspond to the STATCODE * status variable. The bit that is set within the WMAKS variable means that the corresponding warning bit in the STATCODE * variable should generate an F24 fault message, as well as a warning. Unlike warnings, a fault message results in the disabling of the output stage, and the opening of the BTB contact. A reconfiguration of a warning to a fault message can be especially relevant for the following warnings: contouring/following error, threshold detection, hardware limit switch. The value has to be entered in decimal.


See also LASTWMASK