ASCII - Command | ANDB | |||
Syntax Transmit | ANDB [Data] | |||
Syntax Receive | ANDB <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Float | CANBus Object Number | 3508 (hex) | |
DIM | mV | PROFIBUS PNU | 1608 (dec) IND = 1 (dec) | |
Range | 0.0 .. 10000.0 | DPR | 8 (dec) | |
Default | 0 | |||
Opmode | 1, 3 | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 1.0 | |
Function Group | analog I/O | EEPROM | Yes | |
Short Description | Dead band of the analog velocity input signal |
Description
This variable suppresses small analog input signals by setting a dead band zone in which signals are ignored. This function is useful with OPMODE=1 (without higher-level position control). Depending on the operating mode, this parameter applies to analog input 1 or analog input 2 (depending on which setpoint input is used as the source for the velocity value). See ANCNFG for additional information. |