ASCII - Command ANDB    
Syntax Transmit ANDB [Data]    
Syntax Receive ANDB <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 3508 (hex)
DIM mV   PROFIBUS PNU 1608 (dec) IND = 1 (dec)
Range 0.0 .. 10000.0   DPR 8 (dec)
Default 0    
Opmode 1, 3   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group analog I/O   EEPROM Yes
Short Description Dead band of the analog velocity input signal

Description

This variable suppresses small analog input signals by setting a dead band zone in which signals are ignored. This function is useful with OPMODE=1 (without higher-level position control). Depending on the operating mode, this parameter applies to analog input 1 or analog input 2 (depending on which setpoint input is used as the source for the velocity value). See ANCNFG for additional information.