ASCII - Command | ANIN2 | |||
Syntax Transmit | ANIN2 | |||
Syntax Receive | ANIN2 <Data> | Available in | ||
Type | Variable ro | MMI | Yes | |
ASCII Format | Integer32 | CANBus Object Number | 350A (hex) | |
DIM | mV | PROFIBUS PNU | 1610 (dec) IND = 1 (dec) | |
Range | -10000 .. 10000 | DPR | 10 (dec) | |
Default | - | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | ||
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 1.0 | |
Function Group | analog I/O | EEPROM | No | |
Short Description | Voltage at analog input 2 |
Description
The ANIN2 command returns the present value of the voltage at the analog input SW2. |