| ASCII - Command | ANOFF1 | |||
| Syntax Transmit | ANOFF1 [Data] | |||
| Syntax Receive | ANOFF1 <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer16 | CANBus Object Number | 350B (hex) | |
| DIM | mV | PROFIBUS PNU | 1611 (dec) IND = 1 (dec) | |
| Range | -10000 .. 10000 | DPR | 11 (dec) | |
| Default | 0 | |||
| Opmode | All | Data Type Bus/DPR | Integer16 | |
| Drive State | - | Weighting | ||
| Start Firmware | 1.0 | |||
| Configuration | No | Last Change of this Object | 1.0 | |
| Function Group | analog I/O | EEPROM | Yes | |
| Short Description | Analog offset for analog input 1 | |||
Description
| This variable compensates for the offset voltages of CNC controls and the analog input 1 ANIN1 . It can also correct an analog offset from external controls. |