| ASCII - Command | CALCPOSIO | |||
| Syntax Transmit | CALCPOSIO | |||
| Syntax Receive | CALCPOSIO <Data> | Available in | ||
| Type | Command | MMI | No | |
| ASCII Format | Command | CANBus Object Number | 38A6 (hex) | |
| DIM | PROFIBUS PNU | 1734 (dec) IND = 33 (dec) | ||
| Range | DPR | 934 (dec) | ||
| Default | - | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | 3.75 - 5.02 | |||
| Configuration | No | Last Change of this Object | 2.4 | |
| Function Group | drive configuration | EEPROM | No | |
| Short Description | Initialisation of the POS I/O card | |||
Description
| Initialisation of the POS I/O card. This command has to be done once (with no X3C connector plugged in) after error F20 “POSIO data bcc error” occurred. Only for S700: FW 3.75/5.02 |