ASCII - Command CCSAVE    
Syntax Transmit CCSAVE [Data]    
Syntax Receive CCSAVE <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer32   CANBus Object Number -
DIM -   PROFIBUS PNU -
Range 0 , 1   DPR No
Default -    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting  
Start Firmware 2.15    
Configuration No   Last Change of this Object 2.14
Function Group drive configuration   EEPROM No
Short Description Save / reset CANopen communication parameter

Description

Description

CCSAVE ist used to save the CANopen communiaction parameter in object area 1000h – 1FFFh into the drive or to reset the values to default.

Es sind zwei Werte zulässig:

0 – CANopen-communication parameter are set to default. The CAN COB ID's are recalculated for the set CAN address ADDR. The new data are active after drive restart.

1 – CANopen-communication parameter are saved into the drive.