ASCII - Command | DAOFFSET1 | |||
Syntax Transmit | DAOFFSET1 [Data] | |||
Syntax Receive | DAOFFSET1 <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 387C (hex) | |
DIM | mV | PROFIBUS PNU | 1692 (dec) IND = 33 (dec) | |
Range | -500 .. 500 | DPR | 892 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer16 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 3.14 | |||
Configuration | No | Last Change of this Object | 2.3 | |
Function Group | analog I/O | EEPROM | Yes | |
Short Description | Analog Offset Output 1 |
Description
This is an offset that is applied to the D/A converter for analog output 1. The offset value is given in internal units (counts). Scaling is as follows: DAOFFSET1 = 2058 -10V DAOFFSET1 = 1250 0V DAOFFSET1 = 442 10V FW > 5.00 |