| ASCII - Command | DAOFFSET2 | |||
| Syntax Transmit | DAOFFSET2 [Data] | |||
| Syntax Receive | DAOFFSET2 <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Float | CANBus Object Number | 387D (hex) | |
| DIM | mV | PROFIBUS PNU | 1693 (dec) IND = 33 (dec) | |
| Range | -500 .. 500 | DPR | 893 (dec) | |
| Default | 0 | |||
| Opmode | All | Data Type Bus/DPR | Integer16 | |
| Drive State | - | Weighting | 1000 | |
| Start Firmware | 3.14 | |||
| Configuration | No | Last Change of this Object | 2.3 | |
| Function Group | analog I/O | EEPROM | Yes | |
| Short Description | Analog Offset Output 2 | |||
Description
| This is an offset that is applied to the D/A converter for analog output 2. The offset value is given in internal units (counts). Scaling is as follows: DAOFFSET2 = 2058 -10V DAOFFSET2 = 1250 0V DAOFFSET2 = 442 10V FW > 5.00 |