ASCII - Command DIRIN    
Syntax Transmit DIRIN [Data]    
Syntax Receive DIRIN <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer32   CANBus Object Number 389D (hex)
DIM -   PROFIBUS PNU 1725 (dec) IND = 33 (dec)
Range 0...2147483647   DPR 925 (dec)
Default 0    
Opmode All   Data Type Bus/DPR Integer32
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 3.66    
Configuration Yes   Last Change of this Object 2.4
Function Group digital I/O   EEPROM Yes
Short Description polarity of the digital inputs

Description

Defines the polarity of the digital inputs of the drive
DIRIN is a bit parameter. A single bit x of this variable is assigned to the digital input INx.
A bit state of 1 inverts the corresponding digital input.

This function is available only for the inputs IN1,IN2,IN3,IN4 (IN21,IN22 for S700)