ASCII - Command DREF    
Syntax Transmit DREF [Data]    
Syntax Receive DREF <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer8   CANBus Object Number 352C (hex)
DIM -   PROFIBUS PNU 1644 (dec) IND = 1 (dec)
Range 0...34   DPR 44 (dec)
Default 0    
Opmode 8   Data Type Bus/DPR Integer8
Drive State -   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group position loop   EEPROM Yes
Short Description Direction for Homing

Description

The DREF parameter can be used to define the preferred direction of motion for a homing operation and for positioning with a modulo-axes.

Bits 0..3 are used for homing, Bits 4..7 for modulo-axis (POSCNFG=1).

The possible combinations are shown in the table.

If a homing mode with zero puls is selected DREF should be set to 2,18 or 34.

See also POSCNFG
Homing - Direction Modulo - Direction
DREF = 0 negative negative
DREF = 1 positive negative
DREF = 2 shortest distance negative
DREF =4 negative movement without reversing >= version 1.30

DREF =4 homing direction negativ (like DREF=0),no positive movement on reference switch or limit switch

This setting is only usefull for NREF=1,3.
DREF = 5 potitive movement without reversing >= version 1.30

DREF =5 homing direction positive (like DREF=0),no negative movement on reference switch or limit switch

This setting is only usefull for NREF=1,3.
DREF = 16 negative positive
DREF = 17 positive positive
DREF = 18 shortest distance positive
DREF = 32 negative shortest distance
DREF = 33 positive shortest distance
DREF = 34 shortest distance shortest distance