ASCII - Command ERRCNFG    
Syntax Transmit ERRCNFG [Data]    
Syntax Receive ERRCNFG <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer32   CANBus Object Number 3884 (hex)
DIM -   PROFIBUS PNU 1700 (dec) IND = 33 (dec)
Range -2147483648 .. 2147483647   DPR 900 (dec)
Default 83894274 (0x50002002)    
Opmode All   Data Type Bus/DPR Integer32
Drive State     Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.8
Function Group other commands   EEPROM Yes
Short Description behavior of the drive in the case of error

Description

The command ERRCNFG defines the behavior of the drive in the case of error massage Fxx.
If the bit number xx of the ERRCNFG parameter is set to 1, then the corresponding error message FXX+1
generates an immediately power stage disable (no matter what is the setting of ACTFAULT).

Example:
The default value 83894274 (-> 0x0500 2002) disables immediately the output stage in case of error:
F02 Fault over voltage
F14 Output stage fault
F25 Commutation Error
F27 „AS-Option“ Error

In some critical error situations, the output stage is disabled immediately. Then the setting ACTFAULT = 1 has no function.

See also command ERRCODE, ERRCODE *