| ASCII - Command | GEARO | |||
| Syntax Transmit | GEARO [Data] | |||
| Syntax Receive | GEARO <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer32 | CANBus Object Number | 3540 (hex) | |
| DIM | - | PROFIBUS PNU | 1664 (dec) IND = 1 (dec) | |
| Range | 0 .. 2147483647 | DPR | 64 (dec) | |
| Default | 1 | |||
| Opmode | 4 | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | 1.0 | |||
| Configuration | No | Last Change of this Object | 1.0 | |
| Function Group | position loop | EEPROM | Yes | |
| Short Description | Output Factor for Electronic Gearing | |||
Description
| In master/slave applications (OPMODE=4) this parameter can be used to set the master/slave translation ratio. |