ASCII - Command | IPEAKP | |||
Syntax Transmit | IPEAKP [Data] | |||
Syntax Receive | IPEAKP <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Float | CANBus Object Number | 3594 (hex) | |
DIM | A rms | PROFIBUS PNU | 1748 (dec) IND = 1 (dec) | |
Range | 0 ... DIPEAK | DPR | 148 (dec) | |
Default | IMAX | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 1.0 | |
Function Group | current loop | EEPROM | Yes | |
Short Description | positive motor peak rms current |
Description
Positive motor peak rms current. Can be reduced to DICONT or MICONT in I2T fallback condition |