| ASCII - Command | IQFILTTAU | |||
| Syntax Transmit | IQFILTTAU [Data] | |||
| Syntax Receive | IQFILTTAU <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer16 | CANBus Object Number | 388A (hex) | |
| DIM | ms | PROFIBUS PNU | 1706 (dec) IND = 33 (dec) | |
| Range | 0 .. 2000 | DPR | 906 (dec) | |
| Default | 200 | |||
| Opmode | 1,2 | Data Type Bus/DPR | Integer16 | |
| Drive State | Weighting | |||
| Start Firmware | ||||
| Configuration | No | Last Change of this Object | 2.1 | |
| Function Group | other commands | EEPROM | Yes | |
| Short Description | Low-pass filter time constant for slip compensation | |||
Description
| Low-pass filter time constant for slip compensation. Used in V/f Control. Iq is low-pass filtered (smoothed) before it is used for slip compensation. |