ASCII - Command IQFILTTAU    
Syntax Transmit IQFILTTAU [Data]    
Syntax Receive IQFILTTAU <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 388A (hex)
DIM ms   PROFIBUS PNU 1706 (dec) IND = 33 (dec)
Range 0 .. 2000   DPR 906 (dec)
Default 200    
Opmode 1,2   Data Type Bus/DPR Integer16
Drive State   Weighting  
Start Firmware    
Configuration No   Last Change of this Object 2.1
Function Group other commands   EEPROM Yes
Short Description Low-pass filter time constant for slip compensation

Description

Low-pass filter time constant for slip compensation. Used in V/f Control.
Iq is low-pass filtered (smoothed) before it is used for slip compensation.