| ASCII - Command | ISCALE1 | |||
| Syntax Transmit | ISCALE1 [Data] | |||
| Syntax Receive | ISCALE1 <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Float | CANBus Object Number | 3571 (hex) | |
| DIM | A/10V | PROFIBUS PNU | 1713 (dec) IND = 1 (dec) | |
| Range | 0 ... DIPEAK | DPR | 113 (dec) | |
| Default | 15 | |||
| Opmode | 3 | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | 1000 | |
| Start Firmware | 1.0 | |||
| Configuration | No | Last Change of this Object | 1.0 | |
| Function Group | analog I/O | EEPROM | Yes | |
| Short Description | Scaling of Analog Current Setpoint 1 | |||
Description
| Defines the scaling for the analog setpoint input 1 (if it is a current setpoint in OPMODE = 3). The current value that is set here corresponds to the maximum input voltage (10V). |