ASCII - Command | MAXTEMPM | |||
Syntax Transmit | MAXTEMPM [Data] | |||
Syntax Receive | MAXTEMPM <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Float | CANBus Object Number | 3586 (hex) | |
DIM | Ohms or [MTAB units] | PROFIBUS PNU | 1734 (dec) IND = 1 (dec) | |
Range | -6000.0 .. 6000.0 | DPR | 134 (dec) | |
Default | 300 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | 1000 | |
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 2.10 | |
Function Group | temperatures | EEPROM | Yes | |
Short Description | Motor Temperature Switch off Threshold |
Description
The motor temperature for switching off (defined by the resistance in ohms). MAXTEMPM = 0 switches off the monitoring of the motor temperature (F06) In existing temperature characteristic (see MTAB) the units change for the parameter MAXTEMPM and TEMPM of Ohm to the unit that was used in the characteristic definition. see also SLTEMPM, TEMPM, MTAB |