ASCII - Command MDBLIST    
Syntax Transmit MDBLIST [*]    
Syntax Receive MDBLIST <Data>   Available in  
Type Multi-line Return Command   MMI No
ASCII Format String   CANBus Object Number -
DIM -   PROFIBUS PNU -
Range -   DPR No
Default -    
Opmode All   Data Type Bus/DPR -
Drive State -   Weighting  
Start Firmware 2.13    
Configuration No   Last Change of this Object 1.0
Function Group motor   EEPROM No
Short Description List of Motor Data Sets

Description

The MDBLIST command returns the list of contents for the motor database (for the present combination of output stage + feedback). One motor database entry is displayed per line on the screen, in the following format:
motor name, motor number, motor family, amplifier designation

The individual elements are interpreted as follows:
Motor name: a symbolic motor designation (max. length 12 characters).
Motor number: a number that can be used to uniquely identify a particular motor. This number is used to load a data set from the motor database with the MNUMBER command.
Motor family: an additional designation (for internal use only).

If PROMPT 2 is set, a formatted output appears, which is especially suitable for terminal display.

The MDBLIST * command can be used to display the complete list of contents for the motor database. The difference to the output generated by MDBLIST is that the contents also include motor data sets that are not suitable for the present combination of output stage and feedback. These data sets will be displayed, but they cannot be loaded.
Compared with the MDBLIST output, the MDBLIST * output has been enlarged by the columns “Amplifier designation” and “Feedback”. These designations can be used to find out for which output stage or FBTYPE setting this data set was created.
Amplifier designation 6xx, where xx = current rating
Feedback: 0=Resolver, 2=Hiperface, 4=Endat