ASCII - Command MI2T    
Syntax Transmit MI2T    
Syntax Receive MI2T <Data>   Available in  
Type Variable ro   MMI No
ASCII Format Integer8   CANBus Object Number 35A4 (hex)
DIM %   PROFIBUS PNU 1764 (dec) IND = 1 (dec)
Range 0 ... 100   DPR 164 (dec)
Default -    
Opmode All   Data Type Bus/DPR Integer8
Drive State   Weighting  
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group motor   EEPROM No
Short Description Motor I2T load

Description

This variable returns the average current as a percentage of the continuous current (see MICONT). The average current is filtered with the time constant MTIME.