ASCII - Command ML    
Syntax Transmit L [Data]    
Syntax Receive ML <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 3577 (hex)
DIM mH   PROFIBUS PNU 1719 (dec) IND = 1 (dec)
Range 0 .. 200   DPR 119 (dec)
Default 1    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.9
Function Group motor   EEPROM Yes
Short Description Stator Inductance of the Motor

Description

The parameter describes the stator inductance between phase and phase in mH.