ASCII - Command MRS    
Syntax Transmit MRS [Data]    
Syntax Receive MRS <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Float   CANBus Object Number 3686 (hex)
DIM Ohms   PROFIBUS PNU 1990 (dec) IND = 1 (dec)
Range 0 .. 200   DPR 390 (dec)
Default 1    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 2.13
Function Group other commands   EEPROM Yes
Short Description Winding Resistance of the Stator Phase-Phase

Description

The parameter describes the stator winding resistance phase-phase in Ohm