| ASCII - Command | MUR | |||
| Syntax Transmit | MUR [Data] | |||
| Syntax Receive | MUR <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Integer16 | CANBus Object Number | 3886 (hex) | |
| DIM | V | PROFIBUS PNU | 1702 (dec) IND = 33 (dec) | |
| Range | 100 .. 500 | DPR | 902 (dec) | |
| Default | 230 | |||
| Opmode | 1,2 | Data Type Bus/DPR | Integer16 | |
| Drive State | Weighting | |||
| Start Firmware | ||||
| Configuration | No | Last Change of this Object | 2.1 | |
| Function Group | other commands | EEPROM | Yes | |
| Short Description | rated voltage of the induction machin | |||
Description
| MUR is a paramtere for using a induction maschine and describes the rated voltage of the induction motor (in Volt) |