| ASCII - Command | P | |||
| Syntax Transmit | P [Data] | |||
| Syntax Receive | P <Data> | Available in | ||
| Type | Variable ro | MMI | No | |
| ASCII Format | Integer16 | CANBus Object Number | 38D2 (hex) | |
| DIM | Watt [W] | PROFIBUS PNU | 1778 (dec) IND = 33 (dec) | |
| Range | - | DPR | No | |
| Default | - | |||
| Opmode | All | Data Type Bus/DPR | Integer16 | |
| Drive State | - | Weighting | ||
| Start Firmware | ||||
| Configuration | No | Last Change of this Object | 2.11 | |
| Function Group | actual values | EEPROM | No | |
| Short Description | calculated active power (electrical) | |||
Description
| Actual current and voltage command are used to calculate the actual active power that the motor supplied with |