ASCII - Command | PNIP | |||
Syntax Transmit | PNIP | |||
Syntax Receive | PNIP <Data> | Available in | ||
Type | Command | MMI | Yes | |
ASCII Format | String | CANBus Object Number | - | |
DIM | IP-Adresse | PROFIBUS PNU | - | |
Range | [0 … 255].[0 … 255].[0 … 255].[0 … 255] | DPR | No | |
Default | 0.0.0.0 | |||
Opmode | All | Data Type Bus/DPR | - | |
Drive State | Disabled + Reset (Coldstart) | Weighting | ||
Start Firmware | 6.02 | |||
Configuration | No | Last Change of this Object | 2.15 | |
Function Group | fieldbus | EEPROM | Yes | |
Short Description | PROFINET IP Address |
Description
Indicates the (remanently) stored PROFINET IP address. Can be entered manually, but is usually assigned by the Controller. Example: --> PNIP 192.168.0.3 - The value must be a valid IP address. - The valid IP address is entered after the next cold start. |