ASCII - Command | PNIPACT | |||
Syntax Transmit | PNIPACT | |||
Syntax Receive | PNIPACT <Data> | Available in | ||
Type | Variable ro | MMI | Yes | |
ASCII Format | String | CANBus Object Number | - | |
DIM | IP-Adresse | PROFIBUS PNU | - | |
Range | [0 … 255].[0 … 255].[0 … 255].[0 … 255] | DPR | No | |
Default | 0.0.0.0 | |||
Opmode | All | Data Type Bus/DPR | - | |
Drive State | - | Weighting | ||
Start Firmware | 6.02 | |||
Configuration | No | Last Change of this Object | 2.15 | |
Function Group | fieldbus | EEPROM | No | |
Short Description | Currently valid PROFINET IP Address |
Description
Indicates the currently valid PROFINET IP address. Example: -->PNIPACT 192.168.0.4 - PNIP can differ from PNIPACT. - PNIPACT always corresponds to PNIP after cold start. - Can only be changed by Controller (STEP7,TIA) during operation. - There is a flag (temporary) in the Controller, with which the IP address is transferred in PNIP. Attention: If the flag for transfer is not set, PNIP is deleted and receives the value (0.0.0.0). |