ASCII - Command | SWE2 | |||
Syntax Transmit | SWE2 [Data] | |||
Syntax Receive | SWE2 <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer32 | CANBus Object Number | 3606 (hex) | |
DIM | - | PROFIBUS PNU | 1862 (dec) IND = 1 (dec) | |
Range | long int | DPR | 262 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | ||
Start Firmware | 1.0 | |||
Configuration | No | Last Change of this Object | 1.0 | |
Function Group | position loop | EEPROM | Yes | |
Short Description | SW limit switch (biggest position) |
Description
The variable SWE2 contains the position value for the limit switch. The scaling of the position depends on the PGEARI / PGEARO / PRBASE parameters, and is calculated according to the following formula: SWE2[increments] = SWE2[input] * PGEARO / PGEARI 1048576 increments/turn for PRBASE=20 65536 increments/turn for PRBASE=16 SWE1 < SWE2 see also description of SWCNFG |