ASCII - Command T    
Syntax Transmit T [Data]    
Syntax Receive T <Data>   Available in  
Type Command   MMI Yes
ASCII Format Float   CANBus Object Number 360E (hex)
DIM A   PROFIBUS PNU 1870 (dec) IND = 1 (dec)
Range -DIPEAK .. DIPEAK   DPR 270 (dec)
Default -    
Opmode 2   Data Type Bus/DPR Integer32
Drive State Enabled   Weighting 1000
Start Firmware 1.0    
Configuration No   Last Change of this Object 1.0
Function Group current loop   EEPROM No
Short Description Digital current setpoint

Description

The “T” command can be used to define a constant current setpoint <i> (in A).
This current setpoint remains effective until a new T / STOP / OPMODE command is executed.