ASCII - Command UVLTMODE    
Syntax Transmit UVLTMODE [Data]    
Syntax Receive UVLTMODE <Data>   Available in  
Type Variable rw   MMI No
ASCII Format Integer8   CANBus Object Number 3617 (hex)
DIM -   PROFIBUS PNU 1879 (dec) IND = 1 (dec)
Range 0, 1   DPR 279 (dec)
Default 1    
Opmode All   Data Type Bus/DPR Integer8
Drive State Disabled + Reset (Coldstart)   Weighting  
Start Firmware 1.0    
Configuration Yes   Last Change of this Object 1.0
Function Group drive configuration   EEPROM Yes
Short Description Undervoltage Mode

Description

The configuration variable UVLTMODE activates or inhibits the undervoltage monitoring of the amplifier.
If the monitoring is activated (UVLTMODE=1), then the fault message F05 (undervoltage) is generated as soon a s the DC-bus voltage falls below the undervoltage threshold VBUSMIN and the output stage is activated .