| ASCII - Command | VBUSLIM | |||
| Syntax Transmit | VBUSLIM [Data] | |||
| Syntax Receive | VBUSLIM <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | - | CANBus Object Number | 35F5 (hex) | |
| DIM | % | PROFIBUS PNU | 1845 (dec) IND = 1 (dec) | |
| Range | 70...95 | DPR | 245 (dec) | |
| Default | 90 | |||
| Opmode | All | Data Type Bus/DPR | - | |
| Drive State | Weighting | |||
| Start Firmware | ||||
| Configuration | No | Last Change of this Object | 2.6 | |
| Function Group | drive configuration | EEPROM | Yes | |
| Short Description | threshold of the phase failure monitoring | |||
Description
| This parameter describes th threshold of the phase failure monitoring function. The dimension of this bar is % of the avarage DC bus. If the bar of the DC bus for min. 25msec fall below, there will be generatet a warning (n05) or a fault (F19) depending on the settings of PMODE. |